						Items | 
						Specifications | 
			
				| 
						Power | 
						Voltage/frequency | 
						Single phase 220V  50/60Hz   Three phase380V    50/60Hz | 
			
				| 
						Allowable fluctuations | 
						voltage:±15%, frequency:±5% | 
			
				| 
						Control | 
						Frequency range | 
						0-400Hz | 
			
				| 
						Frequency ACCuracy | 
						±0.5% of max frequency | 
			
				| 
						Frequency setting resolution | 
						0.01Hz:Operating“up”and”down”keys on keyboard 
						0.2Hz:Potentiometers analog input | 
			
				| 
						Voltage/frequency characteristics | 
						Voltage 50% -100%  the rated voltage adjustable, Motor rated frequency 25-400Hz(2000Hz) adjustable | 
			
				| 
						Carrier frequency | 
						1.0-15.0KHz/Random carrier modulation | 
			
				| 
						Torque upgrade | 
						0–25.0% adjustable/auto torque upgrade/random V/F curve optional | 
			
				| 
						Maximum Capacity | 
						150% for one minute, 180% for 2s, 200% instant jump. | 
			
				| 
						ACC and DECtime | 
						0.1-6500s | 
			
				| 
						Rated output voltage | 
						Take advantage of the power supply voltage compensation function, if motor rated voltage is 100%,the voltage can be set in the 50 -100% scope(the voltage output should not exceed the input voltage ) | 
			
				| 
						AVR adjust | 
						When the grid voltage fluctuates, changes in the output voltage is very small, remained constant V / F | 
			
				| 
						Automatic energy-saving operation | 
						ACCording to the load conditions, automatic optimize the V / F curves to implement energy saving operation | 
			
				| 
						Standard functions | 
						PID control, ACC and DECtime adjustable, ACC and DECmode variable, Carrier frequency adjustment, Torque upgrade, Current limiting, Speed tracking and restart, Frequency hopping, 
						Frequency fluctuation limite control, Program running, Multi-steps speed,  Pendulum frequency operation, RS485, Analog output, Pulse output frequency | 
			
				| 
						Brake | 
						Energy-consuming braking, DC braking | 
			
				| 
						Frequency setting input | 
						Keyboard number settings, keyboard potentiometers/ external terminal VS: 0~10V, the external terminal AS : 4-20mA, RS485 and signal composition and terminal options | 
			
				| 
						Signal Feedback input | 
						External terminal VS: 0~10V external terminal AS: 4-20mA, RS485 | 
			
				| 
						Input order signals | 
						Start, stop, positive and negative rotating , jog, multi-steps speed, free parking, reset, ACC and DECtime choice, frequency settings channels choice, external malfunctions alarm | 
			
				| 
						External output signal | 
						Relay output, the collector output, 0-10V output, 4-20mA output, the frequency pulse output | 
			
				| 
						Protection function | 
						Overvoltage, undervoltage, current limiting, over-current, overload, electric thermal relays, overheat, pressure stall, data protection | 
			
				| 
						Display | 
						Setting | 
						Function number/data | 
			
				| 
						Running | 
						Output frequency, give frequency, output current, input voltage, output voltage, motor speed, PID feedback, quantitative PID, module temperature, input and output terminal | 
			
				| 
						Fault | 
						Overvoltage, undervoltage, overcurrent, short circuit, phase missing, overload, heat, pressure stall, current limiting, data protection is damaged, current fault operating conditions, historical fault | 
			
				| 
						Condition | 
						Installation sites | 
						Indoor, elevation of not more than 1000 m, no corrosive gases | 
			
				| 
						Temperature, humidity | 
						-10—+40℃, 20%—90%RH(No condensation) | 
			
				| 
						Vibration | 
						Below 20Hz less than 0.5g | 
			
				| 
						Storage Temperature | 
						-25—+65℃ | 
			
				| 
						Installation mode | 
						Wall-mounted mode | 
			
				| 
						Protection degree | 
						IP20 | 
			
				| 
						Cooling Mode | 
						Forced air-cooling |